SALES & TECHNICAL 01751 411965 Mon - Fri 9am - 5pm

Hyco Superflow 90L FLOOR MOUNTED

Excl. Tax: £466.00 Incl. Tax: £559.20

Suitable for hand washing and dish washing where a number of hot water outlets are required such as kitchens, schools, restaurants, washrooms, healthcare environments and offices. The ideal solution for light industrial, commercial and domestic hot water requirements. Can be used for a shower - check that the capacity is suitable for your flow rates and showering time/ frequency.

Heat up time 74 minutes 70% Capacity (10C - 60C)


Capacity 90 Litres | Power 3 kW | Dimensions 1040 x 410 x 410 mm (H x W x D)

OR
SKU
SR90
  • DESCRIPTION
  •  Slender slimline design

    • Mains pressure flow rates

    • Floor standing, no wall mounting necessary
    • Can be used with regular taps, including mixers
    • 3.0 kW element for fast heat up time
    • Element on indicator
    • External mechanical temperature control
    • Easy inspection and maintenance
    • Access to element and thermal cut out beneath the thermostat housing

    • Anode located at the top of the unit meaning only partial drain down is required to inspect or replace
    • Patented technology ensures incoming cold water does not immediately mix with stored hot water   in the tank making more hot water available
    • Glass lined tank, 3 year tank warranty
    • Comes complete with unvented accessory kit
    • Optional thermostatic mixing valve available
    • Erp rating C
    • Cable pre-wired (1.5m), to thermostat housing


    Standing Loss (kWh/day) 1.67

    TECHNICAL SPECIFICATIONS

    Outer Casing
    White powder coated steel

    Heating Element
    Stainless steel incoloy

    Thermostat
    Mechanical up to 65°C

    Water Tank
    Glass lined steel

    Anode
    Replaceable grey magnesium anode (inspect at least annually or more regularly in scale/ aggressive water conditions)

    Insulation
    High density polyurethane foam (CFC free)

    Safety
    Overheat temperature protection (manual reset).
    Factory fitted temperature and pressure relief valve (set at 7 bar 90°C).
    Pressure reducing valve (set at 3 bar).
    Pressure relief valve at 6 bar.
    Use with a thermostatic mixing valve to maintain hot water supplied to user at constant, safe temperature.

    IP Rating
    IPX4

    Installation
    Floor standing only. Must be installed vertically.
    Plan installation carefully to allow sufficient space for all controls and future maintenance.

    Unvented Accessory Kit
    Supplied kit must be fitted.
    Contains expansion vessel with fixing bracket (8L for SR90, 12L for SR140**), inlet group, flexible hose and 2 tundishes.

    Plumbing
    Must be installed by a suitably qualified person.
    Minimum water pressure 1 bar.
    Maximum water pressure to pressure reducing valve 12 bar.
    Working water pressure 3 bar.

    Water Connection
    1/2" MBSP for 90L and 3/4" MBSP for 140L

    Electrical Connection
    Installation must comply with current IET regulations.
    The product should be connected to the fixed wiring of the property via a suitably rated isolating switch with a contact separation of at least 3mm in all poles.

    Approvals
    CE, UKCA, KIWA, Building Regulations

    Standard Warranty
    1 year parts or replacement warranty on electrical components.
    3 year tank warranty.